Technical Data
Pick-up
| Measuring range |
[µm] |
± 100 |
Resolution
|
[bit]
|
16
|
| Stylus radius |
[µm] |
2 - 5 |
Rotary stage
| Rotating angle |
[°]
|
360 |
| Step size |
[°]
|
0.01 |
Workpiece length, max.
|
[cm]
|
45 |
| Workpiece diameter, max. |
[cm] |
20
|
(others easily on request)
|
Drive unit with automatic stylus lift off
| Travel X |
[mm] |
25 |
Travel Y
|
[mm]
|
4
|
System
Dimensions H x W x D
|
[mm] |
1100 x 400 x 400
|
Weight, approx.
|
[kg]
|
70
|
Power supply
|
[V/Hz] |
110-260/50-60 |
Temperature range
|
[°C]
|
10-30 |
| Humidity range |
[%] |
≥ 85 |
Options
Optical sensor
Calculation of roughness parameters
Calculation/display of dominant wavelengths
FFT/ACF functions
Automated or interactive lead structure evaluation
Lead parameters 100% according to Daimler company standard 2008
Automatic wobble compensation
Precision chuck for work piece fixation
Lead standards for calibration of the tool
To Top